4600 Series Electrified Narrow Stile Rim

4600 Electrified Rim

To order, please click here to be redirected to the product page and choose the electrified option required from the menu.

ADA Compliant: True
BHMA Certified: True
UL C/US Listed: True
Contact Hager for Price

Specs

Applications

Heavy Duty Commercial

Certifications
  • ANSI/BHMA A156.3-2014 Grade 1
  • UL305 Listed for Panic Hardware
  • UL/cUL Listed for up to 3 hours for "A" labeled doors
  • UL10C Positive Pressure Rated
  • UL10B Neutral Pressure Rated
  • Complies with ANSI 117.1 for accessible buildings and facilities
Cover

Stainless steel, zinc

Door Thickness

1-3/4" (44mm) - Standard

Electric Modifications
  • RX - Request to Exit
  • RX2 - Dual Request to Exit
  • ALK - Alarm Kit
  • LM - Latchbolt Monitor
  • RXLM - Request to Exit with Latchbolt Monitor
  • MLR - Motor Driven Electric Latch Retraction
  • MLRX- Motor Driven Electric Latch Retraction with Request to Exit
  • MLRXLM - Motor Driven Electric Latch Retraction with Request to Exit and Latchbolt Monitoring
  • MLRLM - Motor Driven Electric Latch Retraction with Latchbolt Monitoring
  • DE - Delayed Egress
Electrical Specifications
  • RX or LM; 3A @125VAC; 2A @ 30 VDC
  • MLR; 1A inrush @24VDC
  • DE; 430mA @ 24VDC signal; 680mA @24VDC Tandem
End Caps

Standard Flush End Cap (Zinc)

Fasteners
  • Wood and machine screws
  • Thru-bolts
Latchbolt Type

3/4" (18mm) throw, pullman type with automatic dead-latching, stainless steel

Notes

Recommended to be used on appropriately reinforced doors

Trim
  • Escutcheon trim
  • Rim cylinder x optional pull
Warranty
  • One year on electrified components
  • Lifetime on hardware components
Wire Requirements
  • Status switches (i.e. RX, LM, etc.) require 2 wires per switch to monitor a normally open (NO) or normally closed (NC) position
  • All devices provide 3 wires per switch so both NO and NC positions can be monitored
  • Monitoring both positions will require 3 wires per switch
Cover Tube
Aluminum
Projection
  • 3" (76mm) in undogged position
  • 2-5/8" (67mm) in electrically dogged position
Stile Width
  • 2-1/8" (54mm) - Minimum stile width required for 1/2" (13mm) blade stop frame and 4950 blade stop strike
  • 3-1/4" (83mm) - Minimum stile width required for single door, 5/8" (16mm) stop and 4920 standard strike
  • 3-3/4" (95mm) - Minimum stile width required for double door x mullion x 4920 strike
  • 2-3/4" (70mm) - Minimum stile width required for double doors with 2" (51mm) mullion and 4952 semi-flush mount strike
  • All stile widths are measured from door edge
By clicking 'Accept All' you consent that we may collect information about you for various purposes, including: Functionality, Statistics and Marketing